Wood stove, heat pump and Home Assistant

Distributing heat from a wood stove using a heat pump fan

I have installed air-to-air heat pumps in two summer houses, both of which have a wood stove or a closed fireplace insert. A logical project was therefore to use the heat pump’s fan to distribute heat from the stove and to use Home Assistant to control an automation. The heat pumps are different – a Bosch in one house and a Mitsubishi in the other – but they share the ability to run in pure fan mode without producing heat.

The initial idea was simple: to use the heat pump’s fan to distribute heat from the stoves. In practice, however, it turned out that whether this makes sense depends largely on how the wood stove receives its combustion air.

Wood stove with outside air intake

In one of the summer houses, the wood stove is supplied with outside air, as is standard in newer installations. The stove therefore does not use indoor air for combustion. Here, I have tested the interaction between the wood stove and the heat pump’s fan.

When the wood stove is properly hot and the heat pump is set to fan-only mode, I find that the heat from the stove is distributed more evenly throughout the house. The heat pump does not work against the stove, and I have not experienced smoke, odour, or draught problems. At present, this is used manually by activating the fan via the configured Home Assistant display.

Closed fireplace insert with indoor air intake

In the other summer house, the situation is different. Here, the closed fireplace insert, which is 18 years old, draws its combustion air directly from the room. The tunnel fireplace has two openings, one of which faces the heat pump’s indoor unit. When I tested the heat pump’s fan in this setup, we experienced a slight smell of smoke in the living room. Not severe, but clear enough to show that the airflow to and from the heat pump affected the conditions around the stove and the chimney.

Closed fireplace insert

It quickly became clear that there was no real benefit in using the heat pump’s fan to distribute heat in this case – quite the opposite. The heat pump needed to be switched off whenever the stove was in use in order to avoid potentially harmful air in the living room. This turned it into a completely different project if it were to be handled automatically.

Measuring temperature alone would not work, as the stove only becomes warm some time after it has been lit. However, in this summer house a Blue Chimney is installed. This is an active smoke extractor designed to ensure proper draft in the chimney and to prevent harmful air and smoke odour in the living room. The extractor does not run continuously, but is activated when the stove is lit and then runs with decreasing intensity over a period of four hours.

The power consumption of the smoke extractor can be measured using a Shelly 1PM, installed as part of the fixed electrical installation. The installation must be carried out by a certified electrician in accordance with applicable electrical regulations. The measured power consumption can then be used in Home Assistant as a reliable signal indicating that the stove is operating.

Here, Home Assistant is not used for comfort optimisation, but as a stop layer. As a starting point, the heat pump must remain switched off as long as there is active firing in the wood stove. When the power consumption of the smoke extractor exceeds 7 watts, this is considered active smoke extraction, and the heat pump remains completely off – including the fan. Only when the smoke extractor is switched off, meaning that power consumption has fallen below 4 watts and to standby level, and the temperature measured on the masonry chimney close to the wood stove using a Shelly BLU H&T is simultaneously below 35 °C, the heat pump is automatically started again. At that point, the stove is effectively extinguished and the system is stable.

About the code
This case describes architecture and control principles, but not specific Home Assistant automations. The actual code will depend on the individual installation. Automations can be generated using AI, provided the AI is given the necessary technical prerequisites as described above.