This case describes a preheating solution that I use in an electrically heated holiday home with electric radiators, electric underfloor heating, and a air-to-air heat pump, controlled via Home Assistant.
In the heating control via Home Assistant, I use four overall modes: Home, Away, Vacation, and Off. Home is normal comfort operation, where the heat pump, electric radiators, and underfloor heating regulate the rooms to the desired temperature. Away is a slight setback, typically used for shorter absences. Vacation is a significantly reduced mode, where electric heating is limited to a minimum for frost protection, and the heat pump is set to its 10-degree function. Off is used when the house is not heated during the summer.

In this holiday home, a Mitsubishi heat pump is installed that supports operation down to 10 degrees. This is suitable for maintenance heating and frost protection, but the built-in 10-degree function cannot be activated via the cloud integration. Instead, the heat pump is set to normal heating with a setpoint of 10 degrees and a high fan speed, which in practice provides an acceptable level of basic heating for the house. You can read more about the integration of this Mitsubishi heat pump in Home Assistant.
Naturally, the goal is to utilize the heat pump as much as possible, since it is 4–5 times more energy-efficient than direct electric heating.
However, the heat pump cannot heat all rooms evenly and therefore cannot function as the sole heat source. On the other hand, it can raise the temperature throughout the entire house. Once the air, walls, and furnishings have been warmed by a few degrees, electric radiators and underfloor heating need to deliver far less output to reach a comfortable temperature.
One way to achieve sufficient comfort is to switch the house to Home mode before arriving at the holiday home. In practice, this means that electric radiators and underfloor heating turn on immediately and begin delivering expensive heat before the heat pump has had the opportunity to do its work.
Instead, preheating is activated in Vacation mode. The house remains in Vacation mode, where electric heating is reduced, and the heat pump is set to a higher setpoint and a higher fan speed. In this way, the temperature of the entire house is raised with low energy consumption. Upon arrival, the house can be switched to Home mode, and electric radiators and underfloor heating are used only for the final fine-tuning in the rooms where the heat pump does not fully suffice.
In Home Assistant, preheating is implemented as a single simple script and one button in the dashboard. The button is only visible in Vacation mode, and when the house is switched to Home mode, the normal heating control automatically takes over.
It is worth noting that the built-in 10-degree function in many heat pumps often has a more advanced internal control strategy than simply using a low setpoint, including a focus on even air circulation and maintenance heating. This and other special functions can, in some cases, only be activated via the manufacturer’s official app or via IR commands, either using the remote control or an IR transmitter for smart home use. In another holiday home with a Bosch Climate 6101i heat pump, which can only be set down to 16 degrees using normal control, I have therefore chosen IR control in order to activate the true 10-degree function. This solution is described in a separate article about IR control of heat pumps.
In practice, this solution provides better comfort upon arrival without significantly increasing electricity consumption, and it shows how a heat pump can be used as an effective source of basic heating even if it cannot cover the entire house on its own.